METHOD & PROCESS PRINCIPLE
Heating, homogenization, water/solids removal and controlled feed transfer reduce instability and heater fouling risk.
UNKA ENGINEERINGEPC CONTRACTORConditions heavy feed before controlled thermal conversion.

Heating, homogenization, water/solids removal and controlled feed transfer reduce instability and heater fouling risk.
Feed tanks, circulation heaters/exchangers, strainers/filters, transfer pumps, mixers and sampling points.
Feed assay, viscosity-temperature curve, water/sediment, CCR/MCR, metals, salt, density, pour point and compatibility.
Design Basis, material balance, PFD, P&ID, equipment and instrument datasheets, line/equipment lists, control narrative, cause-and-effect, layout/3D interfaces, inspection plan, operating and commissioning procedures.
Closed handling, relief/vent/drain routing, alarms and trips, hazardous-area classification, HAZOP actions, maintainable isolation, fire protection and emergency shutdown interfaces.
Heavy fuel oil, atmospheric/vacuum residue and approved compatible heavy hydrocarbon feeds.
API tank/pump practices, ASME B31.3, IEC; EN/DIN or GOST/EAC requirements when contractually selected.
API tank/pump practices, ASME B31.3, IEC; EN/DIN or GOST/EAC requirements when contractually selected.