TANK FARM SYSTEMS

Slop & Oily-Recovery Tanks

Collects off-spec hydrocarbons, drains and recoverable oily streams for controlled reprocessing.

Slop & Oily-Recovery Tanks

METHOD & PROCESS PRINCIPLE

Segregation, settling, water draw-off, mixing and routed return prevent uncontrolled disposal and contamination.

MAIN EQUIPMENT & PACKAGE LIMITS

Slop tanks, mixers, heating if required, water draw, closed drains, pumps, sampling and reprocessing manifold.

CRITICAL DESIGN INPUTS

Stored-fluid properties and classification, required working inventory/autonomy, receipt and dispatch rates, vapor pressure, temperature, corrosion, mixing/heating needs, site wind/seismic/geotechnical data, fire scenario and environmental rules. Expected water/solids, flash point, compatibility and reprocessing route.

ENGINEERING DELIVERABLES

Design Basis, heat and material balance where applicable, PFD, P&ID, datasheets, line/equipment lists, layout and 3D interfaces, control and safeguarding documents, inspection plan, operating and commissioning procedures.

AUTOMATION, SAFETY & HSE

Hazard review, alarms and interlocks, relief/vent/drain philosophy, hazardous-area classification, maintainable isolation, fire protection, emergency shutdown interfaces and environmental controls.

APPLICATIONS & PERFORMANCE BASIS

Refinery closed drains, tank bottoms, off-spec products and recovered hydrocarbons.

CODES, STANDARDS & QUALITY BASIS

API 650/2000, NFPA 30, environmental waste rules; EN/DIN/GOST requirements as applicable.

CONTRACTUAL CODE BASIS

API 650/2000, NFPA 30, environmental waste rules; EN/DIN/GOST requirements as applicable.